DSI smart implant's lower part is slightly tapered and combines a 0.9mm deep thread and a wide thread to allow a better grip on the cancellous bone while enabling a high blood supply around the core of the implant. The Upper thread overlaps with the lower and ends 5.5mm from the top. Two threads progress identically into the bone on the upper and lower parts. It makes installation at an equal pace throughout its entire length. It eliminates any tension between the upper and lower parts of the implant. The design of the groove at the apex enables the implant to cut through the bone and compress it towards the implant's core. The hybrid dual-thread design delivers high support of the implant in the jawbone, by a reduction of the drilling bone volume.
DSI smart implant is developed using histological analysis of the cortical and cancellous bone matter. It is done in order to achieve a reduction of drilling volume along with additional primary stability. The special HDTS (Hybrid Dual Thread Screw) technology uses two different thread types for implant insertion.
There are double-thread thin grooves on the implant at the cortical bone contact and a single-thread groove at the cancellous bone contact. This design reduces the amount of bone removed by a drilling sequence and enables to transfer of the occlusal forces onto the largest area of the bone-implant contact for better capacity allocation. All DSI implants undergo the strictest quality control measures. DSI assures that a high percentage of samples are taken from every batch. Each sample passes a very strict set of tests of cleanliness and conformity. Thus providing minimal rejections afterward. All of the products attend to the highest international standards. All DSI Implants implants are made of titanium alloy Ti-6Al-4V ELI, in accordance with ASTM-F136-02
SLA Surface Treatment:
The classic SLA surface, short of «Sand-blast, Large grit, Acid-etch» is based on large aluminum oxide Al2O3 particles sandblasting technique that generates a macro-roughness on the titanium surface. Sandblasting is followed by an acid-etching batch at high temperatures. As a result, subtle-sized 2-5 micron micropores appear at the implant surface. This unique macro/micro-topography provides an ideal structure for cell attachment while reducing the possibility of bacterial colonization. SLA surface treatment is one of the most used in modern dental implantology. The studies confirmed its strong long-term performance, high mechanical stability, and low odds of developing peri-implantitis. DSI has improved the process, making it hands-free and minimizing the aluminum oxide residuals that may remain on the surface and could significantly impair osseointegration.
DSI smart implants have a unique drilling protocol that requires smart drills in order to deliver the best results. Please click here to go to the smart drills page.
• SLA surface treatment for better osseointegration and reduced bacterial migration.
• High-stability restorations
• Fast Insertion and excellent primary stability
• Survival rates - High and consistent survival rates (over 97% after a five-year follow-up).
• Bone Preservation - Average bone loss of <1 mm after five years (Based on the implant loading time).
• No Peri-Implantitis - Very low prevalence of peri-implantitis over the 5-year follow-up period.
• No aluminum contaminants - Mean a more successful and accelerated process of osseointegration than ever.
• Hybrid Dual Thread design for stable grip at the cortical bone without compressing it.
• Equal distribution of forces along the entire length of the implant.
• Withstands higher axial & vertical loads compared to other implants.
• Enabling high blood supply around the core of the implant.
• Maximum primary stability.
• Ideally suited for both immediate loading and traditional 2-stage protocols.
• Rounded apex with self-tapping threads for optimal surgical flexibility.
• Internal hex connection accepts the full range of the DSI Prosthetic components.
SMI0838, SMI1038, SMI1138, SMI1338: Ø3.75mm H (8, 10, 11.5, and 13mm)
SMI0842, SMI1042, SMI1142, SMI1342: Ø4.2mm H (8, 10, 11.5, and 13mm)
SMI0845, SMI1045, SMI1145, SMI1345: Ø4.5mm H (8, 10, 11.5, and 13mm)
DSI smart implants are high-level improved implants, which combine all the latest technologies and developments in the industry. They deliver great aesthetic results, with a high level of stability and predictability.